WARNING! PLEASE READ AND FOLLOW
THESE INSTRUCTIONS TO AVOID
PERSONAL INJURY OR DEATH:
When working on or around a vehicle, the following
general precautions should be observed at all times.
1. Park the vehicle on a level surface, apply the
parking brakes, and always block the wheels.
Always wear safety glasses.
2. Stop the engine and remove ignition key when
working under or around the vehicle. When
working in the engine compartment, the engine
should be shut off and the ignition key should be
removed. Where circumstances require that the
engine be in operation, EXTREME CAUTION should
be used to prevent personal injury resulting from
contact with moving, rotating, leaking, heated or
electrically charged components.
3. Do not attempt to install, remove, disassemble or
assemble a component until you have read and
thoroughly understand the recommended
procedures. Use only the proper tools and observe
all precautions pertaining to use of those tools.
4. If the work is being performed on the vehicle’s air
brake system, or any auxiliary pressurized air
systems, make certain to drain the air pressure from
all reservoirs before beginning ANY work on the
vehicle. If the vehicle is equipped with an AD-IS
™
air dryer system or a dryer reservoir module, be
sure to drain the purge reservoir.
5. Following the vehicle manufacturer’s
recommended procedures, deactivate the electrical
system in a manner that safely removes all
electrical power from the vehicle.
6. Never exceed manufacturer’s recommended
pressures.
7. Never connect or disconnect a hose or line
containing pressure; it may whip. Never remove a
component or plug unless you are certain all
system pressure has been depleted.
8. Use only genuine Bendix
®
replacement parts,
components and kits. Replacement hardware,
tubing, hose, fittings, etc. must be of equivalent
size, type and strength as original equipment and
be designed specifically for such applications and
systems.
9. Components with stripped threads or damaged
parts should be replaced rather than repaired. Do
not attempt repairs requiring machining or welding
unless specifically stated and approved by the
vehicle and component manufacturer.
10. Prior to returning the vehicle to service, make
certain all components and systems are restored
to their proper operating condition.
11. For vehicles with Antilock Traction Control (ATC),
the ATC function must be disabled (ATC indicator
lamp should be ON) prior to performing any vehicle
maintenance where one or more wheels on a drive
axle are lifted off the ground and moving.
OPERATION & LEAKAGE TESTS
GENERAL
A change in vehicle braking characteristics or a low pressure
warning may indicate a malfunction in one or the other brake
circuit, and although the vehicle air brake system may
continue to function, the vehicle should not be operated
until the necessary repairs have been made and both
braking circuits, including the pneumatic and mechanical
devices are operating normally. Always check the vehicle
brake system for proper operation after performing brake
work and before returning the vehicle to service.
To properly test the function of the ATR-2
™
valve, a pair of
test gauges or gauges of known accuracy must be used.
OPERATION TEST
1. Drain air pressure from all vehicle reservoirs.
FIGURE 11 - TRACTION CONTROL BRAKE APPLICATION
CONTROLLER
BRAKE
VALVE
CHECK VALVE
RELAY PISTON
INLET EXHAUST
REAR AXLE
RESERVOIR
TRAILER SUPPLY
PROP. PISTON
TRACTION
SOLENOID
INLET EXHAUST
SERVICE BRAKE
MODULATOR
Vedere la pagina 6
1 2 3 4 5 6 7 8 9 10 11 12

Commenti su questo manuale

Nessun commento

Dimplex LA16ASR manuali

Manuali dei proprietari e guide per l'utente per Pompe di calore Dimplex LA16ASR.
We fornisce 1 manuali pdf Dimplex LA16ASR per scaricare gratuitamente in base al tipo di documento: Manuale delle Istruzioni






Più prodotti e manuali per Pompe di calore Dimplex

Modelli Tipo di Documento
SIH 11TE Istruzioni per gli Interventi     Dimplex SIH 11TE Operating instructions, 52 pagine
LA 10MR Manuale di Servizio   Dimplex LA 10MR Technical data [en] , 59 pagine
SI 75ZS Manuale Utente     SI 50-130ZS 3-sprachig.book, 48 pagine
LIK 8TE Istruzioni per gli Interventi     Dimplex LIK 8TE Operating instructions, 60 pagine
SIH 6TE Istruzioni per gli Interventi     Dimplex SIH 6TE Operating instructions [it] [pt] , 44 pagine
A16M Manuale di Installazione   Dimplex A16M Installation manual, 40 pagine
SI 37TE Istruzioni per gli Interventi   Dimplex SI 37TE Operating instructions, 21 pagine
A16M Manuale di Installazione   Dimplex A16M Installation manual, 50 pagine
LI 11MER Istruzioni per gli Interventi     Dimplex LI 11MER Operating instructions, 44 pagine
WI 40CG Istruzioni per gli Interventi     Dimplex WI 40CG Operating instructions [en] , 60 pagine
LA 10MR Istruzioni per gli Interventi     Dimplex LA 10MR Operating instructions, 56 pagine
BWP 30 HLW Istruzioni per gli Interventi     Dimplex BWP 30 HLW Operating instructions, 48 pagine
SI 75TER+ Istruzioni per gli Interventi     Dimplex SI 75TER+ Operating instructions, 44 pagine
LI 11ME Istruzioni per gli Interventi     Dimplex LI 11ME Operating instructions, 44 pagine
WI 27CS Istruzioni per gli Interventi   Dimplex WI 27CS Operating instructions, 32 pagine
LI 20TEL Manuale Utente   Heat pump for heating – air source, 127 pagine
SI 10 MR Istruzioni per gli Interventi   Dimplex SI 10 MR Operating instructions, 37 pagine
SI 21CS Istruzioni per gli Interventi     Dimplex SI 21CS Operating instructions, 48 pagine
WI 14 ME Manuale Utente   Instructions d`installation et instructions d`utilisation WI 9-14ME, 20 pagine
SIK 11 ME Istruzioni per gli Interventi   Dimplex SIK 11 ME Operating instructions [en] , 21 pagine