BENDIX BW1596 Manuale Utente Pagina 1

Navigare online o scaricare Manuale Utente per no BENDIX BW1596. BENDIX BW1596 User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 2
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
1
®
Bendix
®
C-5
Cut-Out Cock
SD-07-2601
FIGURE 1
CLAMPING
STUD
VALVEO-RING VALVE SEATS
DESCRIPTION
The C-5
cut-out cock is a manually operated on-off valve.
Cut-out cocks are used in an air brake system where a
manual shut off air lines is desirable such as in trailer and
trailer dolly systems.
OPERATION
Note that in Figure 1 the C-5
cut-out cock uses a metal
ball valve between two valve seats. Rotating the ball valve
90° will either open or close the air passage through the
cut-out cock.
PREVENTIVE MAINTENANCE
Every six months, 1800 operating hours, or 50,000 miles
the cut-out cock should be checked for leakage around the
ball valve and past the stem o-ring. Once each year, 3600
hours, or 100,000 miles the C-5
cut-out cock should be
disassembled, cleaned, and inspected for signs of wear or
deterioration.
LEAKAGE CHECK
With the valve in the closed position and air pressure present
on either side, a soap solution is applied to the side open to
atmosphere. A leakage of not more than a 1" bubble in 5
seconds is permitted.
NOTE: Leakage should be checked in each direction since
it is possible for the valve to seal in one direction
but not the other.
If the cut-out cock leaks excessively or if wear or deterioration
is noted during routine maintenance, it is recommended that
it be replaced with a new unit or repaired with genuine Bendix
parts.
REMOVING AND INSTALLING
REMOVING
Block and hold vehicle by means other than air brakes.
Completely drain all reservoirs. Disconnect air lines from
both sides of the cut-out cock.
BODY
REDUCER
BUSHING
CAP NUT
OPERATING HANDLE
LOCK NUT
STEM
STEM
WASHER
O-RING
Vedere la pagina 0
1 2

Sommario

Pagina 1 - Cut-Out Cock

1®Bendix® C-5™ Cut-Out CockSD-07-2601FIGURE 1CLAMPINGSTUDVALVEO-RING VALVE SEATSDESCRIPTIONThe C-5™ cut-out cock is a manually operated on-off valve.C

Pagina 2 - PERSONAL INJURY OR DEATH:

2INSTALLINGPrior to installing, check, and if necessary, clean or replacelines leading to the cut-out cock.Install the valve taking care the operating